1976 FORD PINTO RECALL - #78V143000
RECALL FOR FUEL SYSTEM, GASOLINE : STORAGE : TANK ASSEMBLY
IN THE EVENT THE VEHICLE IS STRUCK FROM THE REAR, THE FUEL FILLER PIPE COULD DISCONNECT FROM THE TANK OR THE TANK COULD BE PUNCTURED IN THE FORWARD FACE. THIS WOULD RESULT IN FUEL LEAKAGE.
Information provided by the
National Highway Traffic Safety Administration.
•
Send to a friend
•
Hide Form
Recall Details
Vehicle |
1976 FORD PINTO |
|
Manufacturer |
FORD MOTOR COMPANY |
Manufactured between |
8/1/1971 - 7/1/1976 |
Recalled on |
10/12/1979 |
Influenced by |
OFFICE OF DEFECTS INVESTIGATION |
Owners Notified on |
8/22/1978 |
# Affected |
1,400,000 |
Recalled for |
FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY |
|
|
Description |
IN THE EVENT THE VEHICLE IS STRUCK FROM THE REAR, THE FUEL FILLER PIPE COULD DISCONNECT FROM THE TANK OR THE TANK COULD BE PUNCTURED IN THE FORWARD FACE. THIS WOULD RESULT IN FUEL LEAKAGE. |
Consequences |
|
Corrective action |
THE DEALER WILL INSTALL A LONGER FUEL FILLER PIPE HAVING AN IMPROVED SEAL. ALSO, A POLYETHYLENE SHIELD WILL BE INSTALLED ON THE FRONT OF THE FUEL TANK. |
Notes |
VEHICLE DESCRIPTON: PASSENGER VEHICLES.SYSTEM: FUEL; FUEL TANK.CONSEQUENCES OF DEFECT: FUEL LEAKAGE, IN THE PRESENCE OF A SOURCE OF IGNITION,COULD RESULT IN A VEHICLE FIRE AND SERIOUS INJURY TO PASSENGERS. |
See also |
1976 FORD PINTO Recall for STRUCTURE, BODY, BUMPERS
|
Technical Service Bulletins |
|
|