2007 GENIE TZ-34 RECALL - #07V558000
RECALL FOR STRUCTURE
ON CERTAIN TRAILER MOUNTED AERIAL WORK PLATFORM BOOMS, THE TURNTABLE BEARING BOLTS MAY NOT BE TIGHTENED TO SPECIFICATIONS. BOLTS THAT ARE UNDER-TORQUED CAN COME LOOSE OVER TIME.
Information provided by the National Highway Traffic Safety Administration.
•
Send to a friend
•
Hide Form
Vehicle |
2007 GENIE TZ-34 |
|
Manufacturer |
GENIE INDUSTRIES, INC. |
Manufactured between |
5/11/2007 - 9/12/2007 |
Recalled on |
12/12/2007 |
Influenced by |
GENIE INDUSTRIES, INC. |
Owners Notified on |
1/14/2008 |
# Affected |
188 |
Recalled for |
STRUCTURE |
|
|
Description |
ON CERTAIN TRAILER MOUNTED AERIAL WORK PLATFORM BOOMS, THE TURNTABLE BEARING BOLTS MAY NOT BE TIGHTENED TO SPECIFICATIONS. BOLTS THAT ARE UNDER-TORQUED CAN COME LOOSE OVER TIME. |
Consequences |
THIS COULD CAUSE THE TURNTABLE LIFT STRUCTURE TO SEPARATE FROM THE CHASSIS RESULTING IN THE PLATFORM FALLING INCREASING THE RISK OF INJURY OR A CRASH. |
Corrective action |
REPAIR INSTRUCTIONS WILL BE MAILED TO OWNERS ADVISING THEM TO TORQUE THE TURNTABLE BEARING BOLTS TO SPECIFICATIONS. THE RECALL BEGAN ON JANUARY 14, 2008. OWNERS MAY CONTACT GENIE AT 1-800-536-1800. |
Notes |
GENIE RECALL NO. 070009.CUSTOMERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO HTTP://WWW.SAFERCAR.GOV. |
See also |
2007 GENIE TZ-34 Recall for EQUIPMENT
|
|