THE TRACTION SOLENOID EXHAUST CAN BE OBSTRUCTED DUE TO INADEQUATE DRAINAGE AND A BUILD-UP OF ROAD CONTAMINATION

— Recall Campaign #96V095000

THE TRACTION SOLENOID EXHAUST CAN BE OBSTRUCTED DUE TO INADEQUATE DRAINAGE AND A BUILD-UP OF ROAD CONTAMINATION BETWEEN THE MOUNTING BRACKET AND THE SOLENOID HOUSING. THE OBSTRUCTED EXHAUST PREVENTS THE RELAY VALVE CONTROL AIR PRESSURE FROM VENTING AFTER A DIFFERENTIAL BRAKING TRACTION EVENT.

The recall was influenced by the manufacturer with about 771 units affected.


Search:

NHTSA Safety Recall Notice

96V095000
NHTSA Logo
Manufacturer: Volvo Trucks North America
Recall date: March 23, 1996
NHTSA Campaign #: 96V095000
Units affected: 771

Description:
THE TRACTION SOLENOID EXHAUST CAN BE OBSTRUCTED DUE TO INADEQUATE DRAINAGE AND A BUILD-UP OF ROAD CONTAMINATION BETWEEN THE MOUNTING BRACKET AND THE SOLENOID HOUSING. THE OBSTRUCTED EXHAUST PREVENTS THE RELAY VALVE CONTROL AIR PRESSURE FROM VENTING AFTER A DIFFERENTIAL BRAKING TRACTION EVENT.
Consequeces:
THIS CONDITION WOULD KEEP THE REAR AXLE SERVICE BRAKES APPLIED WITHOUT ANY BRAKE PEDAL MOVEMENT BY THE DRIVER INCREASING THE RISK OF A VEHICLE ACCIDENT.
Corrective action:
DEALERS WILL REMOVE THE SUSPECT VALVE AND INSTALL A NEW VALVE THAT HAS A MODIFIED SOLENOID HOUSING WHICH WILL ALLOW FOR SUFFICIENT DRAINAGE AND A NEW VALVE MOUNTING BRACKET WITH INCREASED HEIGHT TO REDUCE ENTRY OF CONTAMINATION.
Notes:
SYSTEM: BRAKES; AIR SYSTEMS. VEHICLE DESCRIPTION: CLASS 8 HEAVY DUTY TRUCKS EQUIPPED WITH A BENDIX ATR TRACTION RELAY VALVE. NOTE: OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME, SHOULD CONTACT VOLVO GM HEAVY TRUCK AT 1-800-528-6586. ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S AUTO SAFETY HOTLINE AT 1-800-424-9393.

Affects the following: