2001 FORD F-250 Complaints
View complaints related to 2001 FORD F-250. The complaints found here are submitted by actual consumers with first hand experience. There are more than 480 complaints submitted for the 2001 FORD F-250. You can submit your own complaint to the NHTSA or call the Hotline, Monday-Friday 8am to 8pm at (888) 327-4236, TTY: (800) 424-9153.
-
2001 FORD F-250 SD- CLEVES, OH
WHEN DRIVING AT NORMAL SPEEDS IN A 2001 F-250 SD 5.4 LITER, SLOWED TO MAKE A STOP AND THEN PROCEEDED ON AND THERE WAS A LOUD POP AND THE TRUCK STARTED RUNNING ROUGH AND MAKING A LOT OF NOISE FROM UNDER THE HOOD. IT TURNED OUT THAT A SPARK PLUG HAD BLOWN OUT OF THE CYLINDER WALL CAUSING THE NOISE AND ROUGH RUNNING. THESE PLUGS HAD JUST BEE REPLACED ABOUT 1 YEAR AGO. THE TRUCK HAD TO BE TOWED TO A REPAIR SHOP ALMOST 100 MILES TO BE REPAIRED. FROM WHAT I UNDERSTAND FROM MY MECHANIC THIS IS AN ONGOING PROBLEM WITH THIS ENGINE. *TR
Source: NHTSA WEB SITE -
2001 FORD F-250 SD- DANBURY, DC
ON VACATION IN MAINE WITH MY 2001 FORD F250 SUPER DUTY I WAS DRIVING DOWN A VERY NARROW, HEAVILY WOODED TWO LANE ROAD AT ABOUT 20 MPH, SUDDENLY AND WITHOUT WARNING A LOUD BANG UNDER THE HOOD OCCURRED. DIFFICULT TO PULL OVER SAFELY AND INVESTIGATE. I HAD TO DRIVE SEVERAL HUNDRED FEET TO TRY TO GET ON A STRAIGHT AWAY FOR SAFETY. THERE WERE SEVERAL LOG TRUCKS THAT HAD TO PASS AS WELL AS OTHER TRAFFIC. I DISCOVERED THAT THE #6 SPARK PLUG HAD "BLOWN OUT" OF ITS HOLE AND DESTROYED THE THREADS, COIL PACK, AND SPARK PLUG. AFTER GETTING THE TRUCK TO A REPAIR FACILITY THE OWNER/MECHANIC INFORMED ME THAT THIS 5.4L TRITON ENGINE DOES THIS ALL THE TIME. HE INFORMED ME THAT HE REPAIRS TWO OR THREE OF THESE A WEEK, IN FACT THERE IS A "REPAIR KIT" AVAILABLE FROM MOST AUTO PART STORES. DOING SOME RESEARCH AFTER GETTING HOME I DISCOVERED THAT THIS IS A CHRONIC FORD PROBLEM THAT THEY REFUSE TO ADDRESS. I WILL BE SELLING THIS TRUCK BECAUSE IT IS A HUGE SAFETY ISSUE FOR ME. I DON'T NEED TO BE STRANDED ON BACK COUNTRY ROADS OR INTERSTATES WITH ANY OF THE OTHER 7 SPARK PLUGS READY TO LAUNCH FROM MY ENGINE WITHOUT WARNING OR CAUSE. *TR
Source: NHTSA WEB SITE -
2001 FORD F-250- COVINGTON , GA
TL* THE CONTACT OWNS A 2001 FORD F250. THE CONTACT STATED WHILE DRIVING 5 MPH THE ENGINE CAUGHT ON FIRE. THERE WERE FLAMES COMING FROM UNDER THE VEHICLE. AFTER STOPPING ON THE SIDE OF THE ROAD, THE ENTIRE VEHICLE WAS ENGULFED IN FLAMES. THE FIRE DEPARTMENT WAS CALLED AND PUT THE FIRE OUT. A REPORT WAS AVAILABLE IF NEEDED. THE ORIGIN OF THE FIRE WAS UNKNOWN. THERE WERE NO INJURIES. THE VEHICLE WAS TOWED TO THE DEALER WHO WILL INSPECT THE VEHICLE. THE MANUFACTURER WAS CONTACTED WHO STATED THEY WILL SEND A REPRESENTATIVE OUT WITHIN THE NEXT TWENTY DAYS TO INSPECT THE VEHICLE. THE FAILURE MILEAGE WAS 220,000. UPDATED 09/27/11 *BF UPDATED 10/05/11
Source: HOTLINE VEHICLE OWNERS QUESTIONNAIRE -
2001 FORD F-250 SD- MEXICO, NY
WHILE DRIVING MY 2001 FORD F250 5.4 L V8 ENGINE POWERED TRUCK THE SECOND (2ND) SPARK PLUG ON THE PASSENGER SIDE OF THE ENGINE BLEW OUT (WAS EJECTED) FROM THE HEAD. THIS WAS AN ORIGINAL SPARK PLUG ON THE 2001 F250 TRUCK WITH 75300 ORIGINAL MILES ON IT. *KB
Source: NHTSA WEB SITE -
2001 FORD F-250 SD- BEND, OR
WE HAVE A 2001 FORD F250 SD, 5.4 LITER TRITON V8. THERE WAS AN AWFUL TICKING NOISE FOR A FEW WEEKS AND ON MONDAY, JULY 4TH, WHILE RESTARTING THE TRUCK IT MADE A HUGE POP NOISE FOLLOWED BY A VERY LOUD TICK THAT SOUNDED LIKE AN EXHAUST LEAK. IT WAS SO LOUD THAT MY 2 YEAR OLD SON WAS SCARED. AFTER LOOKING UNDER THE HOOD, I SAW THE SPARK PLUG HAD BEEN DISLODGED FROM THE HEAD, THE THREADS WERE STRIPPED AND I CANNOT REPAIR IT MYSELF!! THEN AFTER CONTACTING FORD AND MANY AUTO SHOPS WE LEARNED THIS WILL COST US OVER 500 DOLLARS AND THAT THEY HAVE SERVICED OVER 10 VEHICLES IN THE LAST MONTH WITH THE SAME PROBLEM!! WHAT? AND AFTER RESEARCH HAVE NOTICED THAT THERE HAVE BEEN COMPLAINTS DATING BACK TO 2006 AND NO RECOURSE BY OWNERS! WHAT? THIS SAFETY ISSUE NEEDS TO BE FIXED! IT IS SO DANGEROUS. WE ARE REPAIRING OUR VEHICLE USING THE MECHANIC THAT FORD RECOMMENDED, HE WILL BE CHANGING THE COIL AND ADDING PINS TO IT TO ENSURE THAT IT WON'T HAPPEN AGAIN FOR THAT PLUG, BUT THE OTHERS...KEEPING OUR FINGERS CROSSED THAT NOTHING ELSE HAPPENS BEFORE FORD GETS THEIR STUFF TOGETHER AND FIXES THIS!! *TR
Source: NHTSA WEB SITE -
-
2001 FORD F-250 SD- BEND, OR
WE HAVE A 2001 FORD F250 SD, 5.4 LITER TRITON V8. THERE WAS AN AWFUL TICKING NOISE FOR A FEW WEEKS AND ON MONDAY, JULY 4TH, WHILE RESTARTING THE TRUCK IT MADE A HUGE POP NOISE FOLLOWED BY A VERY LOUD TICK THAT SOUNDED LIKE AN EXHAUST LEAK. IT WAS SO LOUD THAT MY 2 YEAR OLD SON WAS SCARED. AFTER CONTACTING FORD AND MANY AUTO SHOPS WE LEARNED THIS WILL COST US OVER 500 DOLLARS AND THAT THEY HAVE SERVICED OVER 10 VEHICLES IN THE LAST MONTH WITH THE SAME PROBLEM!! WHAT? AND AFTER RESEARCH HAVE NOTICED THAT THERE HAVE BEEN COMPLAINTS DATING BACK TO 2006 AND NO RECOURSE BY OWNERS! WHAT? THIS SAFETY ISSUE NEEDS TO BE FIXED! IT IS SO DANGEROUS. WE ARE REPAIRING OUR VEHICLE USING THE MECHANIC THAT FORD RECOMMENDED, HE WILL BE CHANGING THE COIL AND ADDING PINS TO IT TO ENSURE THAT IT WON'T HAPPEN AGAIN FOR THAT PLUG, BUT THE OTHERS...KEEPING OUR FINGERS CROSSED THAT NOTHING ELSE HAPPENS BEFORE FORD GETS THEIR STUFF TOGETHER AND FIXES THIS!! *TR
Source: NHTSA WEB SITE -
2001 FORD F-250 SD- FRENCH CAMP, CA
TL* THE CONTACT OWNS A 2001 FORD F-250 SUPER DUTY. THE CONTACT STATED THE TRANSMISSION WAS LEAKING WHILE DRIVING 25 MPH. THE TRANSMISSION PREVIOUSLY LEAKED ON TWO OCCASIONS AND THE CONTACT HAD TAKEN THE VEHICLE THE DEALER EACH TIME THE FAILURE OCCURRED. THE DEALER REPLACED THE TRANSMISSION PUMP, TORQUE CONVERTER, AND O- RINGS. AFTER THE VEHICLE WAS REPAIRED THE TRANSMISSION CONTINUED TO LEAK. THE CONTACT CALLED THE MANUFACTURER REGARDING THE LEAK AND THEY STATED THAT THE TRANSMISSION WARRANTY EXPIRED AND THERE WAS NOTHING THEY COULD DO TO ASSIST HIM. THE FAILURE MILEAGE WAS 134,000.
Source: HOTLINE VEHICLE OWNERS QUESTIONNAIRE -
2001 FORD F-250 SD- MANVEL, TX
I HAD ANOTHER UNIROYAL LIBERATOR TIRE (265/75/16 E-RATED, LIGHT TRUCK TIRE) FAILURE. BOTH TIRES FAILED WITHIN ONE THOUSAND MILES OF EACH OTHER AND IN THE SAME EXACT WAY. I FILED A COMPLAINT WITH NHTSA ON THE FIRST TIRE APPROX. 2-MONTHS AGO. BOTH TIRES AT ABOUT 35 TO 36,000 MILES, WHILE DRIVING AT SPEEDS APPROACHING 65 MPH FORMED A BALLOON ON TOP OF THE TREAD CAUSING AN IMBALANCE. AFTER CHANGING THE TIRE, IT EXPLODED IN THE BED OF MY TRUCK. IT WAS OBVIOUS TO ME THAT A TREAD SEPARATION HAD OCCURRED. ONE COULD SEE THE SMOOTH AREAS WHERE THE TREAD HAD SEPARATED FROM THE BELT CARCASS VERSUS THE AREA WHERE THE TREAD PULLED AWAY WHEN IT EXPLODED. THESE UNIROYAL LIBERATORS SHOULD BE RECALLED BECAUSE OF HOW QUICKLY THIS FAILURE OCCURS. BOTH TIRES HAD PLENTY OF TREAD AND WERE RUN WITHIN THE PROPER PRESSURE RANGES (70 TO 80 PSI). I HAVE SENT UNIROYAL EMAIL COMPLAINTS CONCERNING THESE TIRES. I HAVE ONE REMAINING ON MY TRUCK THAT WILL BE REPLACED BECAUSE I KNOW IT WILL ALSO FAIL ANY MOMENT. PLEASE DO WHAT YOU CAN TO GET THESE TIRES OFF THE MARKET. THE TIRES DATE OF MANUFACTURE WAS 14TH WEEK OF 2007. *TR
Source: NHTSA WEB SITE -
2001 FORD F-250 SD- ORION, MI
SPARK PLUG EJECTED FROM THE MOTOR WHILE DRIVING. BLEW OUT THE COIL AND STRIPPED THE THREADS. 5.4 LITER TRITON ENGINE WITH 122,000 MILES. *TR
Source: NHTSA WEB SITE -
2001 FORD F-250 SD- FRANKLINVILLE, NJ
I OWN A 2001 FORD F250 SUPER DUTY 4X4 TRUCK. AFTER PURCHASING TRUCK USED, I REPLACED ALL STEERING COMPONENTS WITH O.E EQUIPMENT SPECIFICATIONS AT CERTIFIED REPAIR FACILITIES. ALL FACILITIES CERTIFIED ALL STEERING PARTS IN ORIGINAL SPECIFICATION FORM. DESPITE ALL THIS, THE TRUCK WOULD SHAKE VIOLENTLY UPON HITTING ANY KIND OF ROUGH ROADS OR POTHOLES. AFTER READING OTHER COMPLAINTS, I REALIZED THIS IS DEFECT WITH THE TRUCK EVEN GOING TO 2007 MODEL YEAR. THIS TRUCK IS DANGEROUS!! DANGEROUS!! DANGEROUS!!!!!!!!. NEEDS TO BE RECALLED AND FAIR MARKET VALUE GIVEN TO THE BUYERS. SOMEONE WILL GET KILLED. A DRIVER SHOULD NOT HAVE TO FEAR DRIVING A TRUCK ON ANY ROAD EXCEPT A PERFECTLY SMOOTH ONE WHICH DOES NOT EXIST. I ALMOST DIED DRIVING THIS TRUCK CROSSING THE WALT WHITMAN BRIDGE FROM NJ TO PA. I AM NOT ALONE. NHTSA HAS COMPLAINTS AGAINST THE F250 SD 4X4 GOING INTO 2007 MODEL YEAR. GIVE FAIR MARKET VALUE AND RECALL THE TRUCKS. OWNERS CAN GET THE CREDIT TOWARD PURCHASE OF NEW OR USED FORD TRUCKS MODELS THAT DO NOT SUFFER FROM THIS DEFECT. FORD WILL NOT LOSE IF THEY ACKNOWLEDGE THEIR MISTAKE WHILE NO ONE DIED OR SERIOUSLY INJURED YET!!!!. *TR
Source: NHTSA WEB SITE